Temporary Permanent Power Inspection Requirements During the lifecycle of your project you may have to pay a construction invoice. Please follow these guidelines to help us provide new service when you need it. onditions of Permit: Every permit issued shall become invalid unless the work authorized by such permit is commenced within six (6) months after its issuance or if the work authorized by such permit is suspended or abandoned for a period of six (6) months after the As of August 1, 2021, CHELCO no longer providesFlorida Energy Efficiency Code Compliance calculations. All panel covers must be installed and all disconnects installed. 8. Congratulations, you are now a member and owner of CHELCO! Do keep in mind this is a separate account from the one you may use on FPL.com. CHELCO's annual charity golf tournament raised over $8k, CHELCO powers-up first co-op solar array in NW Florida. Outdoor Lighting Policy Outline. WebPole shall be minimum 6 round or 6x6 treated wood. An FPL project manager will be assigned within two days. Around my area, we do not require 2 rods but compliance with the code is required. and withholding tax and provide workers' compensation for that employee, all as prescribed by law. An FPL Project Manager may need to contact you to verify the type of service that you need or address other issues, such as a certificate of occupancy, deposit requirement or inspection. FPL will send you an email to confirm that your application was received and an FPL Project Manager will be assigned to your project within two days. Certificate of Occupancy (C.O.) WebAPPLICATION FOR TEMPORARY POWER POLE INITIAL SUBMITTAL WILL INCLUDE THE FOLLOWING ITEMS If any submittals do not meet these requirements, they will Spot inspections will be made to check compliance to these rules. Once the bill is ready to be paid, youll receive a new bill notification on your dashboard. Conduit Installation for 3 Phase Open Delta 120/40 Volt Transformer Meter Can and Cabinet C.T. View ourStandard Electrical Service Requirements(SESR). Step 2: Apply for new electric service and get a project ID. Single Phase Overhead Service Entrance (200 Amp or Less), Single Phase Underground Service Entrance (200 Amp or Less), Single Phase Underground Service (400 Amp), Conduit Installation for 3 Phase Open Delta 120/40 Volt Transformer, Transformer Placement in Underground Subdivisions. I am Step 6: A CHELCO crew will install your service. A project may contain one or many work requests and FPL will assign a unique number for each of them. (This form requires use of Adobe Reader; click here to download Adobe Reader for free. 435 N. Macomb Street When there are the appropriate power lines, transformers or other equipment at the site, FPL can install temporary electric service for a fee. To request temporary service, submit a project applicationfor temporary power. An FPL Project Manager will be assigned within two days. You can track the status of your project from your project dashboard. You will need to specify the document type, if the document is confidential, and what project or work request the document relates too. Apply for new CHELCO service onlineor at one of our area offices. Project Members should be anyone on your team who needs to receive updates on FPLs work in relation to project completion. Pole length shall be minimum 17 or 21 depending on weatherhead height requirement. This subsection does not exempt any person who is employed by or has a contract with such owner and who acts in the capacity of a contractor. Step 8: CHELCO will make the final connections to your service. If you continue to have trouble locating a project, contact your FPL Project Manager or visit an FPL Construction Office. | 1.4.0430 | Z5, Florida Conservation and Technology Center, Variable Frequency Drive Control for Compressors. To access your project, login to your account and locate your project on your dashboard. All non-terminated, branch-circuit, current-carrying conductors must be terminated with wire nuts. hbbd```b``^`)d"dICTN7E~e"`}ze "S"! No 120-volt or single-pole circuit breakers should be installed. Existing Services. To update your profile information, login and navigate to your profile page. 100 Amp Meter Pole Installation All of our fees are outlined in the approved Electric Retail Tariff. FPLs standard fees for installing electric service for new construction projects are based on overhead facilities. endstream
endobj
startxref
The building or residence must be for your own use or occupancy. Underground facilities require additional construction and associated costs. Call Tampa Electric's Construction Team at813-635-1500. Inspection requirements: Guidelines should be installed and all disconnects must be permanently-labeled. (888) 223-0800. Completed This tab displays your completed projects and work requests. Step 3: If temporary power is needed, easements may be needed and construction The owner may not delegate the owner's responsibility to directly supervise all work to any other person unless that person is registered or certified under this part and the work being performed is within the scope of that person's license. WebA temporary power pole is a self-contained, separate service, either overhead or underground, installed with a dedicated outdoor weather resistant meter service panel and GFCI protection of all circuits. Right Tree and planting it in the Right Place, Include at least one letter and one number, Exclude spaces or special characters (- & / # , etc.). Generally, if an appointment occurs during business hours, there is no cost. Each project can be tracked and managed using a project number. WebTemporary Power Disconnect An easy way to turn your power off and on Select your location Our site is customized by location. WebA power outlet panel (or POP) is a device designed for outdoor service to meet temporary power requirements at construction sites and recreation vehicle (RV) parks. Our new online service request Step 7: Request your final inspection from the county. Electrical contractors are not allowed to reconnect the electric service. View PDF. WebSingle phase temporary power poles Overhead and underground services available Standard 125 amp-larger services available upon request Licensed electricians perform all temporary power pole installations FEMA trailer electrical hook ups Temp. Check the status of The exemption allows you, as the owner of your property, to act as your own contractor with certain restrictions even though you do not have a license. An FPL Project Manager will be assigned within two days. You've almost completed your electrical connection. Additional Requirements (PDF) FPL shall be consulted so that the Customer's primary service Request electric servicefor your residence, facility or to a temporary pole. With Duke Energys Builder Portal, you have the tools you need to get it done, right at your fingertips. An FPL Project Manager will be assigned to your project within two business days. WebNew residential, commercial, temporary power, lighting projects or standby work. You may review a sample copy of a residential permit application as a PDF, which also includes submittal requirements. 1. You may also build or improve a commercial building, provided your costs do not exceed $75,000. Step 5: CHELCO will prepare your project for construction Meter Can Pedestal Specs Transformer Placement in Underground Subdivisions Underground Residential Service To upload a document, navigate to the Project and Work Request pages and select the Add Document link under the Documents/Photos tab. Temporary poles will need to be inspected by the county. Roofing Permit: WebThese checklists and forms are provided to assist customers in submitting complete permit applications and plans, which simplifies and expedites the permit approval process. https://www.myfloridalicense.com/wl11.asp. Check the status of your projectusing your work request or layout number. You can obtain permits for and construct your own residence as long as the following criteria as stated in Florida Statute, Chapter 489, Section 489.103(7) as follows: Owners of property when acting as their own contractor and providing direct, onsite supervision themselves of all work not performed by licensed contractors, when building or improving farm outbuildings or one-family or two-family residences on such property for the occupancy or use of such owners and not offered for sale or lease, or building or improving commercial buildings, at a cost not to exceed $75,000, on such property for the occupancy or use of such owners and not offered for sale or lease. Webpole permits can be issued: 1. View the color codefor marking underground utility lines. An FPL Project Manager will review your electrical plans and determine which of FPLs standard voltages will meet your electrical service needs. Temporary Power Use of electricity for a temporary use, including but not limited to weekend events, holiday associated sales, and uses approved through the Temporary Use process. 0
Available times may vary by location. If you continue to have difficulties logging in, please contact your local service center to get assistance from alocal project manager. ), Single Phase Overhead Service Entrance (200 Amp or Less) All neutrals must be terminated in panels. An FPL Project Manager will be assigned within two days. A work request or layout number will be sent to your email. It may not be built or substantially improved for sale or lease. This tab is located on the right side of the page below the members tab. 1-17 Location of oil filled pad-mounted equipment (2 of 2) Spec. Learn more about easements. You can also contact a construction office near you. WebGet power turned on and projects underway. Step 4: Contact CHELCO when your meter base is installed and ready for permanent service. Required when any new electrical circuits are added, extended or service is changed. In addition to the above listed codes, include the information (per FBC-B) on title sheet as found on the attached link. %PDF-1.7
%
View PDF. All rights reserved. All panels must be labeled. 60 Amp Temporary Pole Installation To request a disconnect or reconnect, submit a project application. All non View PDF. An FPL Project Manager will be assigned within two days. For additional information, check with your local inspecting authority and FPL Project Manager. Powerful service at your fingertips--wherever you go! Development FPL defines the specific work needed to complete your project. A copy of your invoice is available from the Documents tab on the Project and Work Request pages you may need to select the Go to Documents link in order to see the bill and all other documents. Please refer to the Growth Management Fee Schedule (PDF). Tallahassee, FL 32301. The electrical line that connects the property to FPLs electric system, however, does not require an easement. Youll need this to get started. All KOs in panels, unused circuit-breaker openings and any other openings not listed here must be blanked off in an National Electric Code (NEC)-approved method. C.T. This is an attempt to allow electrical contractors to use air-conditioning equipment only in new-house construction after sheet rock is installed. WebTemporary Power Pole Permit ALL APPLICATIONS SHALL BE SUBMITTED USING THE ONLINE PORTAL https://www2.citizenserve.com/waltonplanning PLEASE BE ADVISED Learn more about therates, rules and regulation and other informationas approved by the Florida Public Service Commission. Change in Service Requirements, Page 11 of 12). Temporary Construction Pole Electric Service Requirements 60 200 AMP Capacities, 120/240-Volt Single-Phase A. ATTACHMENT: The customer must provide point of attachment at the top of the pole. Either an eyebolt or a J-hook is acceptable and must be within the top 6 inches of the pole (12 feet above ground). B.