The wire must have a capacity of 1400 watts or reater. Z;y_C#xeDv6jO*Y6)jr|XO,.Tg]bRkY%L=d,%}zA'ncUrIRVm_7KZNlrI9%RY)cp/~>s>0?0go.[j
% With a normal showerhead, that gives you between 3 and 5 minutes of hot water. With well-planned accommodation and a garage, this large 1310 sq ft, 3-bedroom detached home is ideal for busy working family. 0000003711 00000 n
/en . xref
Install water heater on an exterior wall, with access door opening to outdoors. If sulfur is present in the water supply the two will combine and produce an unpleasant smell. Use the search box to browse our documents database andfind documentation related to your product, such as installation and operating manuals, product drawings, quick start guides, technical data sheets, safety data sheets and more. Install a pressure relief valve in the cold water inlet line to the water heater and attach a drain line from the valve to outside of the coach. DO NOT store or use gasoline or other flammable vapors and liquids in the vicinity of this or any other appliance. Return air shutter to the original position and replace the screw.e. Continue with Recommended Cookies, Home Dometic DOMETIC L.P. Gas Water Heater Instruction Manual, LITERATURE NUMBERMPD 93050L.P. 24, This product can expose you to lead which is, known to the state of California to cause cancer and, birth defects or other reproductive harm. On ELECTRONIC IGNITION MODEL turn operating switch to OFF position and remove the red wire from the left-hand terminal of ECO switch or turn gas OFF at the LP tank. 21,c4cb|t
S!QA2`P&5 Y q#F=lA@&H~d(s@9H1_Si:8 E1tb` =
Fill water heater tank, check all connections for water leaks. Turn gas OFF at the LP tank when the vehicle is in motion. The presence of soot indicates the need to adjust the flame. SERVICE CALLS & QUESTIONS We have removed the fuse and tested it, and it is faulty GAS/ELECTRIC COMBINATION FUNCTIONGAS OPERATION. This water heater is equipped with a temperature and pressure relief valve that complies with the standard for Relief Valves and Automatic Gas Shutoff Devices for Hot Water Systems, ANSI Z21.22.If you use a discharge line, do not use a reducing coupling or other restriction smaller than the outlet of the relief valve. Keep vent and combustion air grill clear of any obstructions. blue bloods do jamie and eddie have a baby; a46 walsgrave junction; prince and susanna hoffs relationship; aftermarket parts for jeep grand cherokee The Dometic WH-6 Series delivers abundant and convenient hot water to ensure a comfortable, mobile lifestyle. 0000016163 00000 n
This manual comes under the category Water heaters & boilers and has been rated by 1 people with an average of a 7.5. Some changes and updates could be incompatible to older devices. Do you have a question about the Dometic and the answer is not in the manual? When the technician removes the mixing valve, cleans the screen (if equipped), and soaks the valve in a hot white vinegar bath, he will also complete the Flushing the Tank procedure as corrosion and sediment from improper Tank Maintenance is the cause of this condition.Altering Dometic Water HeatersIf the water heater has been altered the Warranty will be VoidUse of Aftermarket Heating Element Devices (Hot Rods) can lead to out-of-control heating of water in the tank and catastrophic wet side explosion. Black - 6 Gallon Door (replaces Dometic & Suburban Water Heaters), Arctic White - 6 Gallon Door (fits Dometic/Suburban Water Heaters), White- 6 Gallon Door Assembly (Fits Older Atwood/Dometic Units), KIT, SVC 6GAL DOOR ASM #34 WHT w/Adaptors, Black- 6 Gallon Door Assembly (Fits Older Atwood/Dometic Units), KIT, SVC 6GAL DOOR ASM #44 BLK w/Adaptors. Continue repeating adding water and draining until the particles have been cleared from the water remaining in the tank. This Water Heater is designed and intended for use in a recreational vehicle (hereinafter referred to as "RV") for which it is supplied. The supply cord must be a minimum of 14 AWG and the attachment plug must be rated at 15 amps. 0000002728 00000 n
Installation and service must be performed by a qualified Service Technician, Service Center, OEM or Gas Supplier. This water contains most of the harmful corrosive particles. If the previous two steps did not solve the problem, check the thermal cut-off (FIG 3-I). 0000005810 00000 n
SINEPOWER MCR9 - Standard Inverter Remote Control Manual, PERFECTPOWER DCDC 06, 12, 24 - Voltage Converter Manual, Installation & Operating Instructions Manual, Show all Dometic Automobile Accessories manuals, Show all Dometic Automobile Electronics manuals, Show all Dometic Cables and connectors manuals, Show all Dometic Camera Accessories manuals, Show all Dometic Camping Equipment manuals, Installation And Operating Instructions Manual, Installation Instructions And User Manual, Show all Dometic Indoor Furnishing manuals, Assembly, Installation And Operating Manual, Show all Dometic Kitchen Appliances manuals, Installation, Operation & Maintenance Manual, Show all Dometic Marine Equipment manuals, Show all Dometic Plumbing Product manuals, Operation, Maintenance And Installation Manual, Show all Dometic Portable Generator manuals, Safety And Installation Instructions Manual, Show all Dometic Ventilation Hood manuals, Show all Dometic Water Filtration Systems manuals. 0000109954 00000 n
DO NOT set inlet pressure higher than the maximum indicated on the rating plate of the gas valve (13 W.C.). Do you enjoy taking a cold shower on a winters day? These devices lack critical safety controls. The Dometic water heater is designed for use in a recreation vehicle. This water heater design has been certified by the Canadian Standards Association for installation in recreation vehicles. Do not install a fuse larger than 3 amps. Warning! 94035 02/21 | 2021 Dometic Corporation WH - 6GA, WH - 6GEA, WH - 9GEA EN L.P. Gas Water Heater Installation and Operation Manual . du chauffe-eau, 6.5 Exigences particulires pour les modles EXT, 6.7 Rparation de la soupape de scurit P/T, 6.8 Utilisation dlments dechauffage de leau qui nesontpasdorigine. Neither do we. Check electrode for cracked porcelain (FIG 4-E). The tank should be sized to allow for expansion of approximately 15 oz. Show all Dometic Accessories manuals Accessories For Chillers & Freezers Models Document Type 3851206023 Installation Instructions Adapter Models Document Type COOLPOWER EPS100 Installation And Operating Manual Installation And Operating Manual CoolPower MPS-35 Installation And Operating Manual Installation And Operating Manual COOLPOWER MPS50 With a funnel, carefully pour the solution into the tank. Our products are complemented by a full range of spare parts and accessories, including conversion kits, replacement tanks and access doors. Part-Time RVer, Minimum of 2X annually (Southwest, every (90) day).Reason: The Life of the tank and performance of the water heater are directly affected by water quality! Clean if ame is low, replace assembly if cleaning fails. 0000007673 00000 n
This product is designed to heat water and is not intended to be used as a space heater for hydronic heating. Can you please point us to the best replacement part on read more Robert RV Mechanic Vocational, Technical or Tra. 0000019227 00000 n
0000019145 00000 n
Replace the drain plug and pressure-temperature relief valve. .2, Manuel d'installation et d'utilisation . Do not store or use gasoline or other flammable vapors and liquids in the vicinity of this or any other appliance.WHAT TO DO IF YOU SMELL GAS. Can't find the answer to your question in the manual? Turn on the water heater and allow the water to heat up through a full cycle (this may take up to 45 minutes.) Trip the handle on the relief valve allowing it to snap shut, shut off the hot water faucet, turn on the water supply, and turn the water heater on. . 0000006946 00000 n
0000013113 00000 n
View and Download Atwood MPD 93756 installation operation & maintenance online. Mix a solution of (4) parts white vinegar to (2) parts water. 5. Flush the water heater to remove any sediment. I need to replace my water heater in my 2008 jayco trailer read more startxref
Dometic offers a variety of options so that you can discover an RV water heater that makes sense for you. 0000002523 00000 n
The thermal cut-off fuse could also be unnecessarily activated resulting in a complete shutdown of the water heater requiring replacement of the thermal cut-off. 0000007587 00000 n
To remove these harmful corrosive particles flush the tank with either air or water. Web water heater atwood mpd 93755 installation operation & maintenance. 0000019074 00000 n
Remove the Pressure/Temperature Relief Valve. T
[ZZ9 CFuBXIU,
J2))c on DOMETIC L.P. Gas Water Heater Instruction Manual, DOMETIC 712-TM09 Gravity Discharge Toilet Owners Manual. Set to relieve at 100-125 PSI. 0000003866 00000 n
Install the remote switch in a convenient location. Isolate unit from gas supply line by closing its individual manual shutoff valve during any pressure testing 1/2 PSIG. Even when you are away from home, hot water is a valuable resource you don't want to overlook. Do not operate without water in the tank. DO NOT turn on the gas supply until the gas leak(s) has been repaired. This manual is available in the following languages: English. All Rights Reserved. We stand behind every product we offer and promise to give you the quality solutions you deserve. Rell the tank with fresh water that contains no sulfur. Note: The approximately (2) quarts of water that remain in the bottom of the tank will not cause freeze damage to the tank. The thermal cutoff is a device installed in the power supply line. This material protects thetank from the effects of heavy metals and salts found throughout North America. Dometic Corporation reserves the right to Easy to install and available in a wide range of capacities, Dometic water heaters are reliable, user-friendly and economical. Spread hose clamp and slide toward heat exchange unit past annular groove (5-C) and release. You can also opt for a tankless water heater for on-demand hot water at the touch of a button. It is also equipped with a higher temperature thermostat, raising the storage water temperature.PRESSURE-TEMPERATURE RELIEF VALVE (FIG 3-G)WARNINGSCALDING INJURY. To restore the Air Gap: XT ModelsSpecial RequirementsIf you experience low ow from the hot water faucet or notice the water is not as hot coming from the water heater, you may have to have the Mixing Valve serviced by a Certied Service Technician. Neither do we. . Once the short is corrected, replace the 2 amp fuse with a mini ATO style fuse. WATER HEATERS Form o. Place remote switch in ON position. Shut off the gas supply at the gas container or source. This device will shut off the electrical power and stop heater operation when activated. 0000002923 00000 n
If you would like to change your settings or withdraw consent at any time, the link to do so is in our privacy policy accessible from our home page.. The consent submitted will only be used for data processing originating from this website. Our products are complemented by a full range of spare parts and accessories, including conversion kits, replacement tanks and access doors. When cool, remove the drain plug and drain. $79.99 $39.99. When a cord and plug connection to the power supply are used on the water heater, the power cord must be UL listed as suitable for damp locations, hard or extra-hard usage. kate tweedy and seth hancock. 0000111532 00000 n
DO NOT modify the water heater in any way. Mechanic's Assistant: The RV Mechanic can help you diagnose a blown fuse. Test. Enjoy hot showers no matter if you are in the wilderness or at a rest area on the side of the road. Domain www.dometic.com. For complete shut-down and before servicing: If the heater fails to operate due to high water temperature, a lockout condition occurs (indicator light on). Unscrew the junction box cover to the back of the water heater. Unpredictable wind currents may be created which could cause a flame reversal in the burner tube, which could result in fire damage. It is anodic to these heavy metals and acts much like an anode in a steelglass-lined tank, except it lasts much longer.Use of Aftermarket Heating Elements or Anode Devices are not compatible with Dometic Water Heaters and will void the warranty! When the gas switch is turned on, the unit will make three attempts to light. . All Dometic documents including instructions, guidelines and warnings, and related documentation may be subject to changes and updates. 0000000016 00000 n
576 0 obj
<>stream
of water and pre-charged to a pressure equal to water supply pressure. Great Prices for the best rv water heaters from Dometic. Laserjet p1007 paper jam, hp 280 g2. KIT, SVC 6GAL DOOR ASM #44 BLK w/Adaptors, KIT, SVC 6GAL DOOR ASM #34 WHT w/Adaptors, Black - 6 Gallon Door (replaces Dometic & Suburban Water Heaters), Arctic White - 6 Gallon Door (fits Dometic/Suburban Water Heaters), Dometic Atwood Water Heater Conversion Kit, White- 6 Gallon Door Assembly (Fits Older Atwood/Dometic Units), Black- 6 Gallon Door Assembly (Fits Older Atwood/Dometic Units). Drain the water heater tank and reinstall the drain plug. 0000074738 00000 n
Easy to install and available in a wide range of capacities, Dometic water heaters are reliable, user-friendly and economical. 0000011378 00000 n
Read MAINTENANCE AND CARE INSTRUCTIONS & ELECTRONIC IGNITION MAINTENANCE. Thiswater heater is not for use in marine applications. Caution! When using Romex with a bare earth ground, take care to position ground wire so it does not contact the heating element terminals. 0000123542 00000 n
With an electric heater, you can use external power or get power from your RV's internal battery. Do you enjoy taking a cold shower on a winters day? At least once a year manually operate pressure-temperature relief valve (FIG 3-G). Periodically, compare flame of main burners with FIG 4 and main burner adjustments in HOW TO OPERATE YOUR WATER HEATER. 0000074697 00000 n
. (If using the Pressure Temperature Relief Valve the Support Flange must be removed). 0000003534 00000 n
To view the purposes they believe they have legitimate interest for, or to object to this data processing use the vendor list link below. A gas heater, on the other hand, can do the job in 30 to 40 minutes. The water heater is equipped with a mixing (moderating) valve which mixes cold water with higher temperature water to moderate outlet water to approximately 130F. National Electrical Code ANSI/NFPA No. Main burner and valve manifold must align with each other. All wiring must comply with applicable electrical codes.COMBINATION GAS/ELECTRIC MODELS are designed to operate with gas, electricity, or a combination of both. Dometic uses state-of-the-art engineering and sells its products all over the world, so you know you are getting a high-quality water heater when you shop with us. Do you have a question about the Dometic WH-6GEA or do you need help? 2 FR Chauffe-eau gaz P.L. 0000121441 00000 n
0000014314 00000 n
Dometic Manuals Water Heater WH-6GA Installation and operation manual Dometic WH-6GA Installation And Operation Manual L.p. gas water heater Also See for WH-6GA: Installation and operation manual (52 pages) 1 2 3 4 5 6 7 8 9 10 11 12 13 14 15 16 17 18 19 20 21 22 23 24 25 26 27 28 29 30 31 32 33 34 35 36 37 38 39 40 41 42 43 44 45 46 47 48 of you may flush the tank with air pressure or freshwater. Allow pressure-temperature relief valve to snap shut; close faucet; turn on the water supply. Federal Mobile Home Construction & Safety Standard, Title 24 CFR, part 3280, or when this Standard is not applicable, the Standard for Manufactured Home Installations (Manufactured Home Sites, Communities and Set-Ups), ANSI A255.1 and/or CAN/CSA-Z240 MH Series, Mobile Homes. An effective RV water heater makes your trip that much more enjoyable, giving you the comforts of home no matter where your adventures take you. This manual is available in the following languages: English. Turn off and allow to cool. We have 1 Atwood GC6AA-10E manual available for free PDF download: . Allow complete drainage of both valve and line. DO NOT touch any electrical switch, or use any phone or radio in the vehicle. Ask your question here. Disconnect unit and its individual shut-off valve from gas supply line during any pressure testing of the system in excess of 1/2 PSIG (3.4 kPa, 14 water column [W.C.]).